2025-01-29T22:27:50 Reqif query Roundtrip 1.0 reqif-query New Document reqifcli_text reqifcli_date_time swd-6d380192-9987-5d1a-4443-9c193631b4ef reqifcli_float reqifcli_text reqifcli_rich_text reqifcli_text reqifcli_text sus-8c7a7449-4383-bf8f-1e74-bc2a1d96d87d reqifcli_rich_text reqifcli_date_time reqifcli_text reqifcli_text reqifcli_text 9cdb16f7-5b15-a457-1a22-411a3c2c80ce 15dbaa81-976e-3737-3c3c-068554181691 9789a967-fd9b-9430-6cf5-fe61801f4111 6e351cdf-33f1-383b-2062-a5ce4b27e520 4fcec3b5-3cba-7076-5cf0-3cf62bd796a2 d4ded407-a303-a255-2b8b-c151c9d4e211 The Application does not use an operating System. How ever as, there are PID controlers in the system that need to be timed scheduled the excuction time of all handlers shall be constant. This can be achived through a simple time slicer scheduler Task 7d7c326b-c972-7cfb-00ae-6264eafd6238 Ensure that PID controlers will work as expected. d7fd7f57-0bab-24ec-a188-32c9596c2674 45800201-1f2b-0690-f966-4f39679dee9d a5d39c1e-2b68-af48-4184-d07911593a6d c60558e1-224a-707d-af30-0d814676a483 d6ab385b-9e4f-e18a-d1b1-d8ec0f501f94 5ae7ddba-853e-127c-8d9b-670a164bacf7 a5d39c1e-2b68-af48-4184-d07911593a6d c60558e1-224a-707d-af30-0d814676a483 d6ab385b-9e4f-e18a-d1b1-d8ec0f501f94 5ae7ddba-853e-127c-8d9b-670a164bacf7 9cdb16f7-5b15-a457-1a22-411a3c2c80ce 15dbaa81-976e-3737-3c3c-068554181691 9789a967-fd9b-9430-6cf5-fe61801f4111 6e351cdf-33f1-383b-2062-a5ce4b27e520 4fcec3b5-3cba-7076-5cf0-3cf62bd796a2 b8778a9e-f041-0e2f-6545-a829077c2ced 7ee47f19-1863-f980-cc37-9c4e52dda285 5c1fca10-5400-e023-e018-e272065fdc8a d4ded407-a303-a255-2b8b-c151c9d4e211 Each Board and firmware in the micro controler shall be identified:
  • PCBA Serial shall be factory configured and ReadOnly by end users.
  • Firmware Version in the form YYYY.MM.patch shall be set as read only during build.
  • Firmware Build time shall be set during build time and read only.
  • The software identifier(s) of the legally relevant software. Shall accessible through the CAN interface
7d7c326b-c972-7cfb-00ae-6264eafd6238
45800201-1f2b-0690-f966-4f39679dee9d
9cdb16f7-5b15-a457-1a22-411a3c2c80ce 15dbaa81-976e-3737-3c3c-068554181691 9789a967-fd9b-9430-6cf5-fe61801f4111 6e351cdf-33f1-383b-2062-a5ce4b27e520 4fcec3b5-3cba-7076-5cf0-3cf62bd796a2 d4ded407-a303-a255-2b8b-c151c9d4e211 At startup, the production unit shall not output any flow to patients. Before starting the water pump, it must check that water is in the pump inlet. 7d7c326b-c972-7cfb-00ae-6264eafd6238 Without water the pump can be destroyed if turned on. d7fd7f57-0bab-24ec-a188-32c9596c2674 45800201-1f2b-0690-f966-4f39679dee9d a5d39c1e-2b68-af48-4184-d07911593a6d c60558e1-224a-707d-af30-0d814676a483 d6ab385b-9e4f-e18a-d1b1-d8ec0f501f94 5ae7ddba-853e-127c-8d9b-670a164bacf7 a5d39c1e-2b68-af48-4184-d07911593a6d c60558e1-224a-707d-af30-0d814676a483 d6ab385b-9e4f-e18a-d1b1-d8ec0f501f94 5ae7ddba-853e-127c-8d9b-670a164bacf7 a5d39c1e-2b68-af48-4184-d07911593a6d c60558e1-224a-707d-af30-0d814676a483 d6ab385b-9e4f-e18a-d1b1-d8ec0f501f94 5ae7ddba-853e-127c-8d9b-670a164bacf7 9cdb16f7-5b15-a457-1a22-411a3c2c80ce 15dbaa81-976e-3737-3c3c-068554181691 9789a967-fd9b-9430-6cf5-fe61801f4111 6e351cdf-33f1-383b-2062-a5ce4b27e520 4fcec3b5-3cba-7076-5cf0-3cf62bd796a2 d4ded407-a303-a255-2b8b-c151c9d4e211 The Application component is responsible to start all Handlers (task). 7d7c326b-c972-7cfb-00ae-6264eafd6238 Have a main entry point d7fd7f57-0bab-24ec-a188-32c9596c2674 45800201-1f2b-0690-f966-4f39679dee9d